Review article

Defining the tumour and target volumes for radiotherapy

Burnet NG, Thomas SJ, Burton KE, Jefferies SJ

View Source Source Verified

DoseLab summary

Review of the ICRU target-volume concepts. It summarizes ICRU Report 62's internal margin (for variations in the size, shape and position of the CTV, for example from organ filling or respiration) and set-up margin, and its planning organ at risk volume (PRV): a margin around an organ at risk, analogous to the PTV margin, because systematic and random errors apply to organs at risk as much as to the CTV. It notes that a PRV substantially enlarges the organ and may create dilemmas with target dose, so it is needed only in certain circumstances — around organs whose damage is especially dangerous, such as the spinal cord, a "serial" tissue. Full text read in Europe PMC (PMC1434601).

Why this is useful

A clear, open-access explanation of the ICRU volumes — GTV, CTV, PTV, the internal and set-up margins, and the PRV — and when a PRV is worth adding.

Reference details

Title
Defining the tumour and target volumes for radiotherapy
Authors / organization
Burnet NG, Thomas SJ, Burton KE, Jefferies SJ
Publication / protocol
Cancer Imaging. 2004;4(2):153–161
Version
Pending verification
Year
2004
DOI
10.1102/1470-7330.2004.0054
Disease sites
Pending verification
Topics
Target volumes, Margins, PRV, Contouring, Review
Fractionation context
Pending verification
Last reviewed by DoseLab
2026-10-06