Consensus guideline
Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (IV): Basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapy
Dimopoulos JC, Petrow P, Tanderup K, et al. · GEC-ESTRO
DoseLab summary
GEC-ESTRO gynecological recommendations on MRI for image-guided cervix brachytherapy: field strength, T2-weighted sequences and the para-axial, para-sagittal and para-coronal planes oriented to the applicator. Open access. Citation checked against Europe PMC.
Why this is useful
The MRI sequences and planes used for brachytherapy planning with the applicator in place.
Reference details
- Title
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (IV): Basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapy
- Authors / organization
- Dimopoulos JC, Petrow P, Tanderup K, et al. · GEC-ESTRO
- Publication / protocol
- Radiother Oncol. 2012;103(1):113–122
- Version
- Pending verification
- Year
- 2012
- DOI
- 10.1016/j.radonc.2011.12.024
- Disease sites
- GYN
- Topics
- Brachytherapy, Cervix, MRI, Imaging, Image registration
- Fractionation context
- Pending verification
- Last reviewed by DoseLab
- Pending verification