Clinical resource

Prostate adenocarcinoma definitive ultra-hypofractionated stereotactic EBRT (eviQ ID 4140)

eviQ, Cancer Institute NSW

View Source Source Verified

DoseLab summary

Endorsed eviQ protocol for prostate SBRT. DoseLab's prostate SBRT constraint table reproduces selected values from its organs-at-risk table, keeping eviQ's citation for each.

Why this is useful

Five-fraction prostate SBRT constraints drawn mainly from PACE-B and the TROG NINJA trial, including urethral PRV limits.

Reference details

Title
Prostate adenocarcinoma definitive ultra-hypofractionated stereotactic EBRT (eviQ ID 4140)
Authors / organization
eviQ, Cancer Institute NSW
Publication / protocol
eviQ Radiation Oncology protocol 4140
Version
v.2 — last reviewed 7 November 2024; review due 31 December 2026
Year
2024
DOI
Pending verification
Disease sites
Prostate
Topics
Prostate, SBRT, Dose Constraints, Protocols
Fractionation context
36.25 Gy/5 fx to PTV (40 Gy to CTV)
Last reviewed by DoseLab
2026-09-22

Cited on DoseLab