Consensus guideline

Radiation dose–volume effects in the heart (QUANTEC)

Gagliardi G, Constine LS, Moiseenko V, et al. · QUANTEC

View Source Under Review

DoseLab summary

The heart chapter of the 2010 QUANTEC supplement, covering pericarditis and long-term cardiac effects and the dose–volume relationships reported for them. A later letter in the same journal comments on its breast-cancer conclusions.

Why this is useful

The QUANTEC heart chapter: the dose–volume basis for cardiac limits, drawn largely from lymphoma and breast cohorts with long follow-up.

Reference details

Title
Radiation dose–volume effects in the heart (QUANTEC)
Authors / organization
Gagliardi G, Constine LS, Moiseenko V, et al. · QUANTEC
Publication / protocol
Int J Radiat Oncol Biol Phys. 2010;76(3 Suppl):S77–S85
Version
Pending verification
Year
2010
DOI
Pending verification
Disease sites
Lung, Breast, Other, GI
Topics
Dose Constraints, QUANTEC, Heart, Conventional fractionation
Fractionation context
Primarily conventional fractionation
Last reviewed by DoseLab
Pending verification

Cited on DoseLab