Observational study

Dosimetric predictors of duodenal toxicity after intensity modulated radiation therapy for treatment of the para-aortic nodes in gynecologic cancer

Verma J, Sulman EP, Jhingran A, et al.

View Source Source Verified

DoseLab summary

Review of 105 patients given para-aortic nodal IMRT for gynecologic cancers. A larger duodenal volume receiving 55 Gy predicted late duodenal toxicity; the authors suggest keeping V55 below 15 cm³. DoseLab read the abstract.

Why this is useful

The source of the duodenum V55 Gy <15 cc goal used in conventionally fractionated upper-abdominal plans.

Reference details

Title
Dosimetric predictors of duodenal toxicity after intensity modulated radiation therapy for treatment of the para-aortic nodes in gynecologic cancer
Authors / organization
Verma J, Sulman EP, Jhingran A, et al.
Publication / protocol
Int J Radiat Oncol Biol Phys. 2014;88(2):357–362
Version
Pending verification
Year
2014
DOI
10.1016/j.ijrobp.2013.09.053
Disease sites
GI, GYN
Topics
Duodenum, IMRT, Dose Constraints, Conventional fractionation
Fractionation context
45–50.4 Gy with boost to 60–66 Gy